Jumpers & Load Pi ckup Tool s – 2300
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2303
September 2012
Jumper Cable rated Ø-Ø 15 kV
with EPR Insulation/Jacket
Catalog No.
S10043
S10044
S10045
S10046
Size
AWG
#2
1/0
2/0
4/0
Stranding
259/No. 26
413/No. 24
273/No. 23
437/No. 21
Weight
Per
1000 Ft.
438 lb./197 kg.
598 lb./269 kg.
707 lb./318 kg.
1047 lb./471 kg.
Approx.
Ampacity
Rating, Amps
200
260
300
400
Approx.
Cable
O.D.
0.779"
0.863"
0.914"
1.065"
Approx.
Cond.
Diameter
0.322"
0.404"
0.455"
0.602"
Jumper Cable rated Ø-Ø 25 kV and 35 kV
with EPR Insulation/Jacket
Features & Applications
• Extremely flexible even at low temperatures
• Features insulation/jacket combination resistant to abrasion, oil, heat,
moisture and ozone
• Orange/Red color of mold-cured ethylene-propylene-base coating
imparts high visibility
• AWG size and voltage rating are embossed at 4-foot intervals for easy
identification
• For extended service life, an extruded screen interfaces insulation and
conductor
• This strand screen improves voltage-stress control by adding dielectric
strength and eliminating internal corona
• Insulation and conductor screen meet and exceed ICEA-NEMA standard
S-68-516
• For easy handling in adverse conditions, conductors are extra flexible
alloy-coated copper-stranded rope per ASTM B-189 or B-33
• Ampacity ratings are based on 90°C conductor temperature at 40°C
ambient
Features & Applications
• Extremely flexible even at low temperatures
• Features insulation/jacket combination resistant to abrasion, oil, heat,
moisture and ozone
• Orange/Red color of mold-cured ethylene-propylene-base coating
imparts high visibility
• AWG size and voltage rating are embossed at 4-foot intervals for easy
identification
• For extended service life, an extruded screen interfaces insulation and
conductor
• This strand screen improves voltage-stress control by adding dielectric strength and eliminating internal corona
• Insulation and conductor screen meet and exceed ICEA-NEMA standard S-68-516
• For easy handling in adverse conditions, conductors are extra flexible alloy-coated copper-stranded rope per ASTM
B-189 or B-33
• Ampacity ratings are based on 90°C conductor temperature at 40°C ambient
Weight
Per
1000 ft.
801 lb./ 360.5 kg.
913 lb./410.9 kg.
985 lb./443.3 kg.
Approx.
Ampacity
Rating, Amps
260
300
260
Approx.
Cable
O.D.
1.113"
1.160"
1.287"
Approx.
Cond.
Diameter
0.404"
0.450"
0.404"
Stranding
413
266
413
Size
AWG
1/0
2/0
1/0
Catalog No.
25 kV Cable:
S11272
S11273
35 kV Cable:
S11274
For connectors, see page 2304.