Página 134 - BURNDY

Versión de HTML Básico

TYPES YA-2NU, YA-4NU
Blank Tongue HYLUG™
The Blank Tongue line of Copper Code
HYLUG™ terminals are designed to provide
maximum field flexibility. Scored lines prevent
the drill from walking when trying to drill in
this area. This innovative design allows the
installer to customize the tongue drilling to fit
their specific application while maintaining UL
Listing and CSA certification.
T
B
L
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
* Use PUADP-1 adaptor with U -dies in Y46 HYPRESS™
Installation Tooling
Conductor Min.
Dieless
Mechanical
Hydraulic
Wire
Catalog
*** Bolt Tongue Figure Dimensions
(# of
MD6, OUR840, BCT500HS, Y750, Y46*, Color Die Strip
Number
AWG MM
2
Hole** Width B T L
crimps)
MD7-34R Y500CTHS PAT750 Code Index Length
W8CRT (1)
Y1MRTC (2)
W8CVT (1)
U8CRT (1)
YA8C2NU
#8 AWG — #10 .83 0.81 .12 4.08
MY29-11 (1)
X8CRT (2)
W8CRT (1)
U8CRT (1)
Red 49 7/8
W8CVT (1)
Y1MRTC (2)
MY29-11 (2)
W5CVT (2)
W5CVT (2)
YA6C2NU
#6 AWG — #10 .83 1.12 .12 4.40
MRC840 (2)
W5CRT (2)
W5CRT (2)
U5CRT (2)
Blue 7 1-3/16
Y81KFT (1)
X5CRT (2)
X5CRT (2)
U8CABT (2)
Y81KFTBMH (1)
X8CART (2)
X8CART (2)
PAT81KFT-18V (1)
Y1MRTC (4)
MY29-3 (2)
W4CVT (2)
W4CVT (2)
U4CRT (2)
YA4C2NU
#4 AWG — #10 .83 1.12 .12 4.45
MY29-11 (2)
W4CRT (2)
W4CRT (2)
U6CABT (2)
Gray
8 1-3/16
MRC840 (2)
X4CRT (2)
X4CRT (2)
Y644HS (1)
Y81KFT (1)
YA3C2NU
#3 AWG
25 1/4 .83 1.25 .12 4.62
Y81KFTBMH (1)
W3CRT (2)
W3CRT (2)
U3CRT (2)
White 9 1-5/16
#2 Sol.
PAT81KFT-18V (1)
Y1MRTC (4)
MY29-3 (2)
MY29-11 (2)
W2CVT (2)
W2CVT (2)
YA2C2NU
#2 AWG 35 1/4 .83 1.25 .12 4.64
MRC840 (2)
W2CRT (2)
W2CRT (2)
U2CRT (2)
Brown 10 1-5/16
Y644HS (1)
X2CRT (2)
X2CRT (2)
Y81KFT (2)
Y81KFTBMH (2)
PAT81KFT-18V (2)
Features & Benefits
• Manufactured from seamless high-
conductivity electrolytic copper tubing
with heavy duty wall thickness.
• Internally beveled barrel end.
• Proper compression systems form a highly
efficient electrical connection.
• Dimples located at each end of the scored
line represent the location of the NEMA
standard hole spacing.
• Scored line locates the center of the
Tongue and prevents the drill from walking
when trying to drill in this area.
• Offered in a wide range of code conductor
sizes.
‡ Requires Y60BHU HYPRESS™
** Minimum bolt hole size must be maintained for UL & CSA.
Blue highlighted items are industry standard and most frequently ordered.
Canada: 1-800-387-6487
www.burndy.com
US: 1-800-346-4175
C-14
Compression Connections
BURNDY
®