Página 137 - BURNDY

Versión de HTML Básico

BURNDY
®
Compression Connections
Copper Compression — Code
C-17
US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
Blue highlighted items are industry standard and most frequently ordered.
Conductor
Installation Tooling
Stud
Figure
Mechanical
Hydraulic
Wire
*** Hole Tongue
Dimensions
Dieless
MD6, OUR840,
BCT500HS,
Y35, Y39, Y750,
Color Die Strip
Catalog Number
Fig #
AWG
MM
2
Size Width (B)
(T)
(L)
(# of crimps)
MD7-34R Y500CTHS
Y46*, PAT750 Code Index Length
YAV10-BOX
1
.405 .058 1.02
YAV10R-BOX
3 #14-#10
8-10 .38
.375 .058 .77
YAV10R3-BOX
3
Str
1/4 .47 .405 .047 .83
YAV10T2-BOX
1 #12-#10 6 5/16 .53 .38 .047 1.12
Y8MRB-1 (1)
— — — — 7/16
YAV10T3-BOX
1
Sol
1/4 .47 .405 .047 1.10
YAV10T4-BOX
1
3/8 .56 .38 .047 1.18
Y1MRTC (1)
YA8CL1-BOX
1
1/4 .44 .44 .08 1.26
Y8MRB-1 (1)
YA8CL2-BOX
1 #8 AWG
5/16 .52 .44 .06 1.38 MY29-3 (1)
#8 Weld †
MY29-11 (1)
W8CVT (1) W8CVT (1)
YA8CL3-BOX
1
37/24 10
3/8 .58 .44 .06 1.51
MRC840 (1)
W8CRT (1) W8CRT (1)
U8CRT (1)
Red 49 7/16
YA8CL4-BOX
1 #6 Solid
1/2 .71 .44 .05 1.76 Y81KFT (1)
X8CRT (1)
X8CRT (1)
Y81KFTMBH (1)
YA8CL-BOX
1
8-10 .41 .44 .08 1.16
PAT81KFT-18V (1)
YA6CL-BOX
1
1/4 .45 .54 .08 1.18
W5CVT (1) W5CVT (1)
YA6CL1-BOX
1 #6 AWG
8-10 .41 .54 .09 .99
W5CRT (1) W5CRT (1)
U5CRT (1)
Blue 7 5/8
Y1MRTC (1)
X5CRT (1)
X5CRT (1)
MY29-3 (1) X8CART (1) X8CART (1)
YA6CL3-BOX
1
5/16 .52 .54 .07 1.24 MY29-11 (1)
MRC840 (1)
W5CVT (1) W5CVT (1)
YA6CL4-BOX
1
3/8 .63 .54 .06 1.28 Y81KFT (1)
W5CRT (1) W5CRT (1)
U5CRT (1)
#6 AWG
Y81KFTMBH (1)
X5CRT (1)
X5CRT (1)
UBCABT (1)
Blue 7 5/8
YA6CL6-BOX
1
1/2 .75 .54 .12 1.60 PAT81KFT-18V (1)
X8CART (1) X8CART (1)
W5CRT (1) W5CRT (1)
YA5CL-BOX
1 #5 AWG
1/4 .44 .81 .07 1.65
W5CVT (1)
X5CRT (1)
U5CRT (1)
Blue 7 7/8
X5CRT (1)
W5CVT (1)
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
TYPES YA-L, YA-L-TC
COPPER COMPRESSION
TERMINAL
UL Listed 90° C,
600 Volts to 35 kV
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
B
B
B
T
T
T
L
45°
90°
L
L
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
CRIMP
DIE AND COLOR
CODE INFORMATION
INSPECTION
WINDOW
BEVELED
ENTRY
Fig. 1
45°
90°
† The MM
2
conductor size listed is for both Class 2 and
Class 5 conductor.
See tooling section of this catalog for complete tool and
die listings.
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
Note:
All dimensions shown are for reference only.