Página 141 - BURNDY

Versión de HTML Básico

Conductor
Installation Tooling
Stud
Figure
****
Mechanical
Hydraulic
Wire
*** Hole Tongue
Dimensions
Dieless
MD6, OUR840,
BCT500HS,
Y35, Y39, Y750,
Color Die Strip
Catalog Number
Fig #
AWG
MM
2
Size Width (B)
(T)
(L)
(# of crimps)
MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
Y8MRB-1 (1)
MY29-3 (1)
YA8CLNT6
1
**
6 .29 .44 .09 1.08
MY29-11 (1)
#8 AWG 10
MRC840 (1) W8CVT (1)
X8CRT (1)
U8CRT (1)
Red 49 1/2
Y81KFT (1)
YA8CLNT8
1
8 .33 .44 .09 1.18 Y81KFTMBH (1)
PAT81KFT-18V (1)
YA6CLNT6
1 #6 AWG — 6 .29 .54 .09 1.17 Y1MRTC (1) W5CVT (1)
X5CRT (1)
U5CRT (1)
Blue 7 7/8
YA4CLNT10
1 #4 AWG — # 10 .40 .81 .09 1.73 MY29-3 (1)
W4CVT (1)
X4CRT (1)
U4CRT (1)
Gray 8 7/8
YA3CLNT14
1 #3 AWG
1/4 .41 .88 .09 1.82 MY29-11 (1)
YA3CLNT516
1 #2 Sol.
25
5/16 .49 .88 .09 1.80 MRC840
W3CVT (1) W3CVT (1)
U3CRT (1)
White 9 15/16
YA2CLNT10
1
# 10 .48 .88 .11 1.80 Y644HS (1)
YA2CLNT14
1
1/4 .50 .88 .11 1.80 Y81KFT (1)
#2 AWG 35
Y81KFTMBH (1)
W2CVT (1)
X2CRT (1)
U2CRT (1)
Brown 10 15/16
YA2CLNT516
1
5/16 .49 .88 .11 1.82
PAT81KFT-18V (1)
YA1CLNT10
1
# 10 .50 .88 .10 2.23
YA1CLNT14
1
#1 AWG 50
1/4 .50 .88 .10 2.23
W1CVT (1)
X1CRT (1)
U1CRT (1)
Green 11 15/16
YA25LNT10
1
# 10 .62 .88 .12 2.28
MY29-3 (1)
YA25LNT14
1
1/4 .48 .88 .12 1.93
MY29-11 (1)
YA25LNT516
1
1/0 AWG —
5/16 .62 .88 .12 2.28
MRC840 W25VT (2)
X25RT (2)
U25RT (1)
Pink 12 15/16
YA25LNT38
1
3/8 .62 .88 .12 2.18
Y644HS (1)
YA26LNT10
1
# 10 .62 .94 .13 2.62
Y81KFT (1)
YA26LNT14
1
1/4 .48 .94 .13 2.02
Y81KFTMBH (1)
YA26LNT516
1
2/0 AWG 70
5/16 .62 .94 .13 2.62
PAT81KFT-18V (1) W26VT (2)
X26RT (2)
U26RT (1)
Black 13 1
YA26LNT38
1
3/8 .72 .94 .12 2.48
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
NARROW TONGUE
TYPE YA-L-NT
COPPER COMPRESSION
NARROW TONGUE
TERMINAL
UL Listed 90° C,
600 Volts to 35 kV
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
CRIMP
DIE AND COLOR
CODE INFORMATION
INSPECTION
WINDOW
BEVELED
ENTRY
L
45°
90°
L
L
B
B
B
T
T
T
Fig. 1
45°
90°
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** The MM
2
conductor size listed is for Class 2 and Class 5
conductor.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
**** Y644M is not recommended for standard barrel length
#6 AWG HYLUG™.
See tooling section of this catalog for complete tool and
die listings. Use ONLY color-coded die recommendations
for -FXconnectors. For nest/indentor system contact
factory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
Note:
All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
C-21
BURNDY
®
Compression Connections
Copper Compression — Code — Narrow Tongue