Página 143 - BURNDY

Versión de HTML Básico

Conductor
Installation Tooling
Stud
Figure
Mechanical
Hydraulic
Wire
*** Hole Tongue
Dimensions
Dieless
MD6, OUR840,
BCT500HS,
Y35, Y39, Y750 Color Die Strip
Catalog Number
Fig #
AWG
MM
2
Size Width (B)
(T)
(L)
(# of crimps)
MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
.
MRC840 (2)
YA8CTC10
1
#8 AWG
# 10 38 .81 .08 1.57
Y8MBR-1 (1)
#8 Weld †
Y1MRTC (2)
W8CVT (2)
X8CRT (2)
YA8CTC14
1
37/24 10
1/4 .41 .81 .08 1.69
Y81KFT (1)
W8CRT (2) W8CVT (2)
U8CRT (2)
Red 49 1
#6 Sol
Y81KFTMBH (1)
X8CRT (2)
W8CRT (2)
YA8CTC38
1
3/8 58 .81 .06 1.88
PAT81KFT-18V (1)
MRC840 (2)
YA6CTC10
1
# 10 .41 1.12 .09 1.89 MY29-3 (2)
MY29-11 (2) W5CVT (2) W5CVT (2)
Y644HS (1)
W5CRT (2) W5CRT (2)
U5CRT (2)
YA6CN
1
#6 AWG —
1/2 .83 1.12 .12 2.64 Y1MRTC (2)
X5CRT (2)
X5CRT (2)
U8CABT (2)
Blue 7 1-3/16
Y81KFT (1) X8CART (2) X8CART (2)
Y81KFTMBH (1)
YA6C
1
1/4 .41 1.12 .09 1.81
PAT81KFT-18V (1)
Y1MRTC (2)
MRC840 (2)
YA5C
1
1/4 .44 1.12 .07 1.98
MY29-3 (2)
MY29-11 (2)
W5CVT (2) W5CVT (2)
#5 AWG —
Y644HS (1)
W5CRT (2) W5CRT (2)
U5CRT (2)
Blue 7 1-3/16
.
Y81KFT (1)
X5CRT (2)
X5CRT (2)
YA5CN
1
1/2 83 1.12 .12 2.67
Y81KFTMBH (1)
PAT81KFT-18V (1)
MRC840 (2)
YA4CTC10
1
# 10 .49 1.12 .09 1.94 MY29-3 (2)
MY29-11 (2) W4CVT (2) W4CVT (2)
#4 AWG
Y644HS (1)
W4CRT (2) W4CRT (2)
U4CRT (2)
Gray 8 1-3/16
Y81KFT (1)
X4CRT (2)
X4CRT (2)
U6CABT (2)
YA4C
1
1/4 .50 1.12 .09 1.87
Y81KFTMBH (1)
PAT81KFT-18V (1)
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
TYPES YA, YA-TC
UNINSULATED COPPER
COMPRESSION TERMINAL
UL Listed 90° C,
600 Volts to 35 kV
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
CRIMPS
DIE AND COLOR
CODE INFORMATION
NO INSPECTION
WINDOW
BEVELED
ENTRY
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
B
B
B
T
T
T
L
45°
90°
L
L
Fig. 1
45°
90°
† The MM
2
conductor size listed is for Class 2 and Class 5
conductor.
See tooling section of this catalog for complete tool and
die listings. Use ONLY color coded die recommendations
for -FX connectors. For nest/indentor system contact fac-
tory.
• Available undrilled. Add suffix U to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
Note:
All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
C-23
BURNDY
®
Compression Connections
Copper Compression — Code — Long Barrel — No Inspection Window