Conductor
Installation Tooling
Stud
Figure
Mechanical
Hydraulic
Wire
*** Hole Tongue
Dimensions
Dieless
MD6, OUR840,
BCT500HS,
Y35, Y39, Y750,
Color Die Strip
Catalog Number
Fig #
AWG
MM
2
Size Width (B)
(T)
(L)
(# of crimps)
MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
MRC840 (2)
MY29-3 (2)
YA4CTC38
1
3/8 .58 1.12 .08 2.25
MY29-11 (2)
Y644HS (1)
W4CVT (2) W4CVT (2)
U4CRT (2)
#4 AWG —
Y1MRTC (4)
W4CRT (2) W4CRT (2)
U6CABT (2)
Gray 8 1-3/16
Y81KFT (1)
X4CRT (2)
X4CRT (2)
YA4CN
1
1/2 .83 1.12 .12 2.69
Y81KFTMBH (1)
PAT81KFT-18V (1)
MY29-3 (2)
YA3CTC14
1
1/4 .55 1.25 .09 2.23 MY29-11 (2)
#3 AWG
Y644HS (1)
YA3C
1 #2 Solid
25
5/16 .55 1.25 .09 2.30 Y81KFT (2)
W3CRT (2) W3CRT (2)
U3CRT (2)
White 9 1-1/2
YA3CTC38
1
3/8 .61 1.25 .08 2.42 Y81KFTMBH (2)
YA3CN
1
1/2 .81 1.25 .12 2.86 PAT81KFT-18V (2)
Y1MRTC (4)
YA2CTC10
1
# 10 .61 1.25 .11 2.10
MRC840 (2)
MY29-3 (2)
W2CVT (2) W2CVT (2)
YA2CTC14
1
#2 AWG 35
1/4 .60 1.25 .11 2.23
MY29-11 (2) W2CRT (2) W2CRT (2)
U2CRT (2)
Brown 10 1-5/16
Y644HS (1)
X2CRT (2)
X2CRT (2)
YA2C
1
5/16 .61 1.25 .11 2.29
Y81KFT (2)
YA2CN
1
1/2 .83 1.25 .12 2.88 Y81KFTMBH (2)
PAT81KFT-18V (2)
YA1CTC10
1
# 10 .68 1.38 .10 2.27
Y1MR (4)
MRC840 (2)
MY29-3 (2)
W1CVT (2) W1CVT (2)
YA1C
1
#1 AWG 50
5/16 .68 1.38 .10 2.45
MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2)
U1CRT-1 (2)
Green 11 1-7/16
Y644HS (1) X1CRT-1 (2) X1CRT-1 (2)
U4CABT (2)
Y81KFT (2)
YA1CN
1
1/2 .83 1.38 .12 3.06 Y81KFTMBH (2)
PAT81KFT-18V (2)
MRC840 (4)
YA25TC10
1
# 10 .75 1.38 .12 2.30
MY29-3 (2)
MY29-11 (2) W25VT (4) W25VT (4)
YA25
1
1/0 AWG —
5/16 .75 1.38 .12 2.48
Y644HS (1)
W25RT (4) W25RT (4)
U25RT (2)
Pink 12 1-7/16
Y81KFT (2)
X25RT (4)
X25RT (4)
U2CABT (2)
YA25TC38
1
3/8 .75 1.38 .12 2.61 Y81KFTMBH (2)
PAT81KFT-18V (2)
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(Continued)
UL Listed 90° C,
600 Volts to 35 kV
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
B
B
B
T
T
T
L
45°
90°
L
L
Fig. 1
45°
90°
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and
die listings. Use ONLY color coded die recommendations
for -FX connectors. For nest/indentor system contact fac-
tory.
• Available undrilled. Add suffix U to catalog number
(example: YA25U).
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
Note:
All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
Canada: 1-800-387-6487
www.burndy.com
US: 1-800-346-4175
C-24
Compression Connections
BURNDY
®
Copper Compression — Code — Long Barrel — No Inspection Window