Página 172 - BURNDY

Versión de HTML Básico

Conductor
Installation Tooling
Stud
Figure
Mechanical
Hydraulic
Wire
*** Hole Tongue
Dimensions
Dieless
MD6, OUR840,
BCT500HS,
Y35, Y39, Y750,
Color Die Strip
Catalog Number
Fig #
AWG
MM
2
Size Width (B)
(T)
(L)
(# of crimps)
MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
Y1MRTC (2)
YAZ8CTC10
1
# 10 .41 .75 .08 1.58
Y8MRB-1 (2)
MY29-3 (2)
YAZ8CTC14
1 37/24
**
1/4 .44 .75 .08 1.58
MY29-11 (2)
W8CVT (2) W8CVT (2)
#8 Weld
10
MRC840 (2)
W8CRT (2) W8CRT (2)
U8CRT (2)
Red 49 7/16
#8 AWG
Y81KFT (1)
X8CRT (2)
X8CRT (2)
YAZ8CTC38
1
3/8 .58 .75 .06 1.89
Y81KFTMBH (1)
PAT81KFT-18V (1)
Y1MRTC (2)
YAZV6CTC14FX
1
1/4 .48 .75 .08 2.03 MY29-3 (2)
MY29-11 (2)
61/24
**
MRC840 (2)
W5CVT (2) W5CVT (2)
#6 Weld
16
Y644HS (1)
W5CRT (2) W5CRT (2)
U5CRT (2)
Blue 7 1-3/16
YAZV6CTC38FX
1
#6 AWG
3/8 .58 .75 .06 1.77 Y81KFT (1)
X5CRT (2)
X5CRT (2)
Y81KFTMBH (1)
PAT81KFT-18V (1)
91/24
YAZV4CTC14FX
1
105/24
1/4 .55 1.25 .09 2.21 Y1MRTC (4) W4CVT (2) W4CVT (2)
#4 Weld
MY29-3 (2) W4CRT (2) W4CRT (2)
U4CRT (2)
Gray 8 1-5/16
YAZV4CTC38FX
1
#4 AWG
3/8 .58 1.25 .08 2.39 MY29-11 (2) X4CRT (2)
X4CRT (2)
MRC840 (2)
YAZV2CTC14FX
1 125/24
1/4 .68 1.38 .10 2.39 Y644HS (1)
W2CVT (2) W2CVT (2)
150/24
35
Y81KFT (1)
W2CRT (2) W2CRT (2)
U2CRT (2)
Brown 10 1-7/16
YAZV2CTC38FX
1 #2 Weld
3/8 .68 1.38 .10 2.57 Y81KFTMBH (1)
X2CRT (2)
X2CRT (2)
YAZV2CTC12FX
1 #2 AWG
1/2 .83 1.38 .09 3.01
PAT81KFT-18V (1)
MY29-3 (2)
.
MY29-11 (2)
MRC840 (2) W1CRT-1 (2) W1CRT-1 (2)
YAZV1CTC14FX
1 175/24 — 1/4 75 1.38 .12 2.42 Y644HS (1)
W1CVT (2) W1CVT (2)
U1CRT-1 (2)
Green 11 11/16
Y81KFT (1)
X1CRT-1 (2) X1CRT-1 (2)
Y81KFTMBH (1)
PAT81KFT-18V (1)
ONE HOLE HYLUG™
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
TYPES YAZ, YAZV
COPPER COMPRESSION
TERMINAL
UL Listed 90° C,
600 Volts to 35 kV
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
CRIMP
DIE AND COLOR
CODE INFORMATION
INSPECTION
WINDOW
BEVELED
ENTRY
T
T
90°
L
L
45°
L
B
T
B
B
Fig. 1
45°
90°
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™
** The MM
2
conductor size referenced here is for both Class
2 and Class 5 conductor.
*** The MM
2
conductor sizes listed are the recommendations
for Class 5 conductor.
See tooling section of this catalog for complete tool and
die listings. Use ONLY color-coded die recommendations
for -FX connectors. For nest/indentor system contact fac-
tory.
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
Note:
All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
Canada: 1-800-387-6487
www.burndy.com
US: 1-800-346-4175
C-52
Compression Connections
BURNDY
®
Copper Compression — Flex — Long Barrel — Inspection Window