Página 222 - BURNDY

Versión de HTML Básico

TYPE YCHC
C-TAP COPPER CRIMPIT™
90° C
Note:
To properly use tap 2 and/or tap 3 conductors in YCHC
connector a conductor from the tap 1 cable range must
be included in the tap 1 groove.
‡ To obtain covers made of polyethylene remove suffix-FR
(example: CFO). CFO is not flame retardant.
Features and Benefits
• Wide range of run/tap combinations includ-
ing Class B code I and locomotive flexible
conductor combinations. All (B/B, B/I, I/I)
combinations are recommended.
Each connector accommodates many
cable combinations, allowing maximum
flexibility for the design and installation
of a system.
• Color-coded on the connector that
matches the die.
Provides matched system for fast and
easy installation.
• Each connector has a recommended
insulating cover available. Flame retardant
type CF-FR covers meet oxygen index
28 and UL94 V-O requirements.
A complete insulated UL Listed instal-
lation is provided.
• Die index embossed on connector after
completion of crimp.
Permanent inspectability of installed
connector is insure consistently reliable
and dependable connections.
* Use PUADP-1 adaptor with U dies in Y46.
See tooling section of Master Catalog for complete tool
and die listings.
For applications requiring flame retardant cover, use
either a CCFBG-FR (Clear) or CFBG-FR (Black) cover and
YH2C2C connector by ordering YH8C8CWCC (Clear) or
YH8C8CWC (Black).
Die
BURNDY
Flame Retardant Cover
Condutor Sizes Code/(Flex) Cable
Tooling († No. of Crimps)
Index &
Catalog
Clear
Black
Color Emboss-
Strip
Number
Cat. No.
Cat. No.
Main
Tap 1
Tap 2 Tap 3 Y35 † Y750 † Y46* † Code ment
H W L Length
1000-750
1000-750
YCHC44TC44 CCFR-FR
CFR-FR
(750-500)
(750-500)
— — — — P1102 1 White 1102 3.59 1.73 1.16 1-1/4
750-500
750-350
YCHC39TC39 CCFR-FR
CFR-FR
(550-500)
(550-350)
— — — — P1103 1 Blue
1103 3.12 1.53 1.06 1-1/8
750-500
350-2
2-6 Str./Sol.
8-14
YCHC39TC31 CCFR-FR
CFR-FR
(550-500)
(250-2)
(2-8)
(8-14)
— — — — P1103 1 Blue
1103 2.96 1.53 1.31 1-3/8
750-500
2-6 Str./Sol.
8-14
YCHC39TC2
CCFR-FR
CFR-FR
(550-500)
(2-8)
(8-14)
— — — — P1103 1 Blue
1103 2.66 1.53 1.31 1-3/8
500-4/0
500-4/0
YCHC34TC34
CCFN-FR
CFN-FR
(350-4/0)
(350-4/0)
— — U1104 2 P1104 1 Brown 1104 2.97 1.38 1.00 1-1/4
500-4/0
250-2
2-6 Str./Sol.
YCHC34TC29
CCFN-FR
CFN-FR
(350-4/0)
(4/0-2)
(2-8)
— — U1104 2 P1104 1 Brown 1104 2.45 1.26 .88
1
500-4/0
2-6 Str./Sol.
8-14
YCHC34TC2
CCFN-FR
CFN-FR
(350-4/0)
(2-8)
(8-14)
— — U1104 2 P1104 1 Brown 1104 2.45 1.26 .88
1
250-2
250-2
YCHC29TC29
CCFDXFR
CFD-FR
(4/0-2)
(4/0-2)
— — U997 1 U997 1 Orange 997 2.12 .98 .94
1
250-2
2-6 Str./Sol.
8-14
YCHC29TC2
CCFD-FR
CFD-FR
(4/0-2)
(2-8)
(8-14)
— — U251 1 U251 1 Red
251 1.78 .97 .81
1
2-6 Str./Sol.
2-6 Str./Sol.
8-14
YCHC2TC2
CCFO-FR
CFO-FR
(2-8)
(2-8)
(8-14)
U-C 1 U-C 1 U-C 1 Brown
C
1.22 .60 .81
1
8-12
8-12
YCHC8TC8
(8-12)
(8-12)
U-240 1 U-240 1 U-240 1 Red
240
.53 .35 .56 5/8
Note:
All dimensions shown are for reference only.
Electro Tin
Plated
Blue highlighted items are industry standard and most frequently ordered.
Canada: 1-800-387-6487
www.burndy.com
US: 1-800-346-4175
C-102
Compression Connections
BURNDY
®
Copper Compression — C-Tap