Página 227 - BURNDY

Versión de HTML Básico

TYPES YSH
H COPPER CRIMPIT™
COPPER SPLIT
COMPRESSION WYE TAP
CONNECTOR
Type YSH heavy duty connectors are
designed for insulated underground wye
splices. The split H copper CRIMPIT™ con-
nector is longer than our standard H copper
CRIMPIT™ and is suitable for use on high
voltage (15 kV) power cables with copper
conductors. The connectors can not be used
with oil filled or mass impregnated cables
since no oil stop is provided. The connector
is installed with standard BURNDY
®
HYPRESS™ tools and is made of tin-plated
electrolytic copper.
Features and Benefits
• Accommodates a wide range of run/tap
copper cable combinations including both
flexible and code combinations. All (B/B,
B/I, I/B, I/I) combinations acceptable.
Each connector has many copper cable
combination applications allowing
maximum flexibility for the design and
installation of a system.
• Tap grooves function independently from
each other. Use of one tap is required.
Balance may be used or left empty.
Provides maximum design and instal-
lation flexibility.
TAP 1
TAP 1
TAP 3
TAP 2
Fig. 1
Fig. 2
• Color code on the connector matches
installation die.
Provides matched system for fast and
easy installation.
• Die index embossed on connector after
completion of crimp.
Permanent inspectability of installed
connectors to ensure consistently reli-
able and dependable connections.
• Insulation is not provided. Insulation can
be obtained from Raychem (800-272-
9243) type HVSY Splice kits for 15 kV
installations.
A complete IEEE 404 15 kV installation
is provided.
Expanded Tap 1 Components
Expanded Catalog Number
Tap 1 Range
YSH-292C-E
#2
YSH-2925-E
1/0
Die
Conductor Sizes Code Expanded Tap 1
Index
(Flex Cable)
Tooling (†Number of Crimps)
&
Catalog
Color Emboss-
Strip
Number Fig. Main Tap 1
Tap 2 Tap 3 Y750 † Y46*
† Code ment
H W L Length
250-2 250-2
U654
YSH2929
1
(4/0-2)
(4/0-2)
U654 (4)
P654
(4)/(2) Purple 654
1.85 .90
500-4/0 250-1/0 1-6 Str./Sol. 8-14
U1104
YSH3429
2
(350-4/0)
(4/0-1/0)
(1-8)
(8-14)
U1104 (4)
P1104
(4)/(2) Brown 1104 2.23 1.31
500-250 500-4/0
U1104
YSH3434
1
(350-4/0) (350-4/0)
U1104 (4)
P1104
(4)/(2) Brown 1104 2.43 1.15 3.00
750-350 350-1/0 1-6 Str./Sol. 2-14 — — PYFR
YSH3931
2
(550-500) (350-1/0)
(1-8)
(2-14)
— —
2 Yellow K-R 2.97 1.50
750-350 750-350
PYFR
YSH3939
1
(550-500) (550-350)
— —
2 Yellow K-R 2.97 1.50
See Application Notes Below
* Use PUADP-1 adaptor with U dies in Y46. The Y46 and P
dies result in a smooth crimp surface and is recommend-
ed for voltages above 600 V.
Main Conductor
YSH Connector
Main Conductor
Tap Conductor
For continuous and/or tap
connections refer to table
for conductor ranges.
Strip Length 1–1/2
Conductor ends remain visible
when conductor is split
Due to thickness of underground wire insulation the minimum
recommended strip length from the connector edge is 1 inch.
See tooling section of this catalog for complete tool and
die listings.
† Number of crimps per connector. U -dies require double
crimps.
Note:
All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
C-107
BURNDY
®
Compression Connections