Página 260 - BURNDY

Versión de HTML Básico

US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
Blue highlighted items are industry standard and most frequently ordered.
E-7
BURNDY
®
Grounding
HYGROUND
®
Compression
TYPE YGL-C
HYGRID CROSS CONNECTOR
An irreversable compression ground grid
cross connector which allows adjustment of
the compression elements prior to installa-
tion. Only six connectors and four dies are
required to install all combinations from #6
solid through 500 kcmil. UL467 Listed.
Acceptable for direct burial in earth and con-
crete. Prefilled with PENETROX™ compound
and strip sealed.
NOTES:
• Before crimping, both connector elements can
be turned on rod diameter “D” to any desired
position.
• Clean rust and/or protective coatings from rebar
prior to installation.
• When attaching connector to ground rod,
ground rod must be embossed with appropriate
PRECRIMP™ die. For connections that must
meet IEEE 837 requirements UPRECRIMP - type
PRE crimp dies must be used for maximum
clamping retention.
ORDERING INFORMATION
1.
Where a “U” or “PU” die is recommended with Y45
HYPRESS™, a PT6515 adapter must be used.
2. Where a “U” or “PU” die is recommended with the Y46
HYPRESS™, a PUADP-1 adapter must be used.
Polarized die for the PAT750-18V.
UL96 Listed for Lightning Protection.
467 96
Catalog
Cable to Cable
Cable to Ground Rod
To Rebar
Number
Element “A”
Element “B”
Element “A”
Element “B”
Element “A”
YGL2C2
#6 Sol. (.162) – #2 Str. (.292)
{59500} – {59500}
#6 Sol. (.162) – #2 Str. (.292)
YGL29C2
#1 Str. (.332) – 250 kcmil (.575)
{59500} – {59500}
#6 Sol. (.162) – #2 Str. (.292)
3/8 – 1/2
{98500} – {131500}
1/2 – 5/8 Rod
YGL29C29
#2 Str. (.292) – 250 kcmil (.575)
#2 Str. (.292) – 250 kcmil (.575)
#2 Str. (.292) – 250 kcmil (.575)
#3 – 4 Rebar
{65500} – {131500}
{65500} – {131500}
YGL34C2
#6 Sol. (.162) – #2 Str. (.292)
#6 Sol. (.162) – #2 Str. (.292)
5/8 – 3/4
YGL34C29
250 kcmil (.575) – 500 kcmil (.813)
#2 Str. (.292) – 250 kcmil (.575)
5/8 – 3/4 Rod #2 Str. (.292) – 250 kcmil (.575)
YGL34C34
250 kcmil (.575) – 500 kcmil (.813)
250 kcmil (.575) – 500 kcmil (.813)
#5 – 6 Rebar
Dimensions in brackets { } represent lightning
protection conductors.
* These connectors can only be installed using the Y750,
Y45, or Y46 HYPRESS™ with the recommended dies.
These connectors CANNOT be installed with the Y35 and
Y39 HYPRESS™.
Installation Tools, Die Set Catalog Number (Number of Crimps)
Catalog
Y750/Y35/Y39 HYPRESS™ PAT750-18V
Y45 HYPRESS™
Y46 HYPRESS™
Number
Element “A” Element “B” Element “A” Element “B” Element “A” Element “B” Element “A” Element “B”
YGL2C2
U-0 (1)
U-0 (1)
U-0 (1)
U-0 (1)
U-0 (1)
U-0 (1)
U-0 (1)
U-0 (1)
YGL29C2
U997 (1)
U-0 (1)
U997P (1)
U-0 (1)
U997 (1)
U-0 (1)
U997 (1)
U-0 (1)
YGL29C29
U997 (1)
U997 (1)
U997P (1)
U997P (1)
U997 (1)
U997 (1)
U997 (1)
U997 (1)
S998 or
P998 or
YGL34C2*
PU998 (1)
U-0 (1)
PU998 (1)
U-0 (1)
PU998 (1)
U-0 (1)
PU998 (1)
U-0 (1)
S998 or
PU998 or
YGL34C29
*
PU998 (1)
U997 (1)
PU998 (1)
U997P (1)
PU998 (1)
U997 (1)
PU998 (1)
U997 (1)
YGL34C34*
U1011 (3)
U1011 (3)
U1011 (3)
U1011 (3)
S1011 (3)
S1011 (3)
P1011 (3)
P1011 (3)
Catalog
Number
B
B-B
C
C-C
D
L
R
YGL2C2
1.09
YGL29C2
1.09
.313
.31
YGL29C29
.75
.75
1.66
1.66
.500
.50
YGL34C2
1.09
.313
2.50
.31
YGL34C29
2.09
1.66
.500
.50
YGL34C34
1.10
1.10
2.28
2.28
.750
.75
Ground Rod
Dia.
PRECRIMP Dies
1/2
UPRECRIMP 12
5/8
UPRECRIMP 58 U2CABT
3/4
UPRECRIMP 34
IEEE-837