Página 589 - BURNDY

Versión de HTML Básico

TYPES YFM-CR,
YFM-CP
MOLIMITER™ ASSEMBLY
With DURICOMP™ Shell and
Rubber Sleeve for Insulated
Cables
The MOLIMITER™ is used for fusing under-
ground cables at junction points. The unit is
designed for use with the BURNDY
®
MOLE™
and provides Limiter protection for cables
For conductor sizes not listed call customer service.
For Use on
Dimensions in Inches
For Connection
Paper
(Max.
to MOLE™ Use
Installation Information
For Use on Insulated Cable
Socket
HYPRESS™ & Indentor Die
Rubber
Cable-Oil
Dia.
and Nut
Y34A Y34BH Y44B
App.
Insulated
Tight
Over
Assembly Z Cone MOLE™ with
with
with Number Ship
Cable
Cable
Cable Socket Insul.)
See
See
Outlet
Y34PR Y34PR Y44R of
Wt. in
Size Catalog No.
Catalog No.
A
L
O.D.
Page K-32 Page K-33 Size
Nest Die
Indents Lbs.
4/0 Str.
YFM28CR YFM28CP
1
9-3/4 1-7/8 Z28NR
Z2828
A
A28D B28D E28D 1
1.1
250 kcmil
YFM29CR YFM29CP
1
9-3/4 1-7/8 Z29NR
Z2929
A
A29D B29D E29D 1
1.1
300 kcmil
YFM30CR YFM30CP
1-1/8 10-5/16 2-3/16 Z30NR
Z3030
A
A30D B30D E30D 2
1.7
350 kcmil
YFM31CR YFM31CP
1-1/8 10-5/16 2-3/16 Z32NR
Z3132
A
A31D B31D E310
2
1.8
400 kcmil
YFM32CR YFM32CP
1-1/8 10-5/16 2-3/16 Z32NR
Z3232
A
A32D B32D E32D 2
1.9
No Nest
500 kcmil
YFM34CR
YFM34CP
1-11/32 11-11/16 2-3/8 Z34NR
Z3434
A
A34D
Die Req’d.
E34D 2
2.6
750 kcmil
YFM39CR YFM39CP
1-1/2 12-3/16 2-9/16 Z34NRB Z3434
B
— — E39D 2
3.4
which terminate at the MOLE™. The cable
end is installed in the MOLIMITER™ cable
socket (see Installation Information in table
below) and then the MOLE™ end is installed
TYPE YFM-CPL
LONG MOLIMITER™
ASSEMBLY
With DURICOMP™ Shell and
Rubber Sleeve for Paper-Lead
Cables
The Long MOLIMITER™ differs from the
standard MOLIMITER™ only in its extra long
cable socket. This socket, with the end seam
in the MOLE™ outlet Socket and Nut assem-
bly. MOLIMITERs which have burned clear
may be quickly replaced. For time current
characteristics see the technical section.
sealed oil tight, is preferred by some for use
on paper insulated cables. Time-current char-
acteristics are shown in the technical section.
For proper HYPRESS™ installation, see table
below.
Dimensions in Inches
For Connection
(Max.
to MOLE™ Use
Installation Information
Cable
Socket
HYPRESS™ & Indentor Die
Dia.
and Nut
Y34A Y34BH Y44B
Over
Assembly Z Cone MOLE™ with
with
with Number Ship
Cable
Catalog
Insul.)
See
See
Outlet
Y34PR Y34PR Y44R of
Wt. in
Size
Number
A
L
O.D.
Page K-32 Page K-33 Size
Nest Die
Indents Lbs.
4/0 Str.
YFM28CPL
1
9-3/4
1-7/8
Z28NR
Z2828
A
A28D B28D E28D 1
1.0
250 kcmil
YFM29CPL
1
9-3/4
1-7/8
Z29NR
Z2929
A
A29D B29D E29D 1
1.0
300 kcmil
YFM30CPL
1-1/8
10-5/16 2-3/16
Z30NR
Z3030
A
A30D B30D E30D 2
1.7
350 kcmil
YFM31CPL
1-1/8
10-5/16 2-3/16
Z32NR
Z3132
A
A31D B31D E31D 2
1.7
400 kcmil
YFM32CPL
1-1/8
10-5/16 2-3/16
Z32NR
Z3232
A
A32D B32D E32D 2
1.8
No Nest
500 kcmil
YFM34CPL
1-11/32 11-11/16 2-3/8
Z34NR
Z3434
A
A34D
Die Req’d.
E34D 2
2.5
750 kcmil
YFM39CPL
1-1/2
12-3/16 2-9/16 Z34NRB Z3434
B
— — E39D 2
3.2
K-52
Canada: 1-800-387-6487
www.burndy.com