Página 59 - elastimold

Versión de HTML Básico

Separable Connectors
200A Loadbreak
CABLE ACCESSORIES
Insulated Cap 15kV
68D G
N7
w/ Ground and 25kV
27 D G
N7
Test Point
35kV
376D G
N7
Grounding Plug 15kV
6 GP
(1/0 AWG x 6’
25kV
272GP
Ground Lead)
Grounding
15kV
60GL
Elbow 25/35kV
370GL
N12
(1/0 AWG x 6’
Ground Lead)
Feed-Thru
15kV
6 T
25kV
27 T
35kV
37 T
N6
35kV
373 T
Feed-Thru
15kV
6 TV
Vertical
25kV
27 TV
35kV
373 TV
Adjustable Bracket
15kV
6 T2-AB
N23
2-point Feed-Thru 25kV
27 T2-AB
N23
Adjustable Bracket
15kV
6 T3-AB
N23
3-point Feed-Thru 25kV
27 T3-AB
N23
Adjustable Bracket
15kV
6 T -AB
N23
4-point Feed-Thru 25kV
27 T -AB
N23
Feed-Thru 15/25kV
K 60 W T
Well
Feed-Thru 15/25kV
K 60 W TV
Well Vertical
Insulated
15kV
6 S P
N20
Parking Bushing 25kV
272S P
N20
35kV
372S P
N21
15kV
6 S P
N20,23
25kV
27 S P
N20,23
Test Rod
ALL
370T
Bushing Well
15/25kV
276BWP
Plug
35kV
276BWP
Assembly Tool
ALL
200AT
N8
Refer to the
W
and
X
tables on pages 38 and 39 for sizing to cable
insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
C TACTS, P BES, PLUGS,
CABLE ADAPTE S A D JU CT S
C T UED
PAGE 7.
200 Amp Loadbreak
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
Elbow
15kV
65L -W5X
N2,3,4,5
Connector
Use Tables W1 and X1
25kV
275L -W5X
N2,3,4,5
Use Tables W16 and X1
35kV
375L -W5X
N2,3,5
Use Tables W3 and X2
Elbow
15kV
66L -W5X
N2,3,4,5
Connector
Use Tables W1 and X1
w/ Test Point
25kV
276L -W5X
N2,3,4,5
Use Tables W16 and X1
35kV
376L -W5X
N2,3,5
Use Tables W3 and X2
Jacket Seal
15kV
65L JS-W5X
N2,19
Elbow
Use Table W1 (B&C
Connector
sizes only) and
Table X1
25kV
275L JS-W5X
N2,19
Use Tables W16
and X1
Jacket Seal
15kV
66L JS-W5X
N2,19
Elbow
Use Tables W1 (B&C
Connector
sizes only) and
w/ Test Point
Table X1
25kV
276L JS-W5X
N2,19
Use Tables W16
and X1
Repair Elbow 15kV
67EL -W5X
N5,10,18
Connector
Use Tables W5 and X1
25kV
273EL -W5X
N5,10,18
Use Tables W5 and X1
Repair Elbow 15kV
68EL -W5X
N5,10,18
Connector
Use Tables W5 and X1
w/ Test Point
25kV
27 EL -W5X
N5,10,18
Use Tables W5 and X1
Replacement
15kV
67 L -W5X
N5,11,13
Elbow
Use Tables W4 and X1
25kV
273 L -W5X
N5,11,13
Use Tables W2 and X1
Replacement
15kV
68 L -W5X
N5,11,13
Elbow
Use Tables W4 and X1
w/ Test Point
25kV
27 L -W5X
N5,11,13
Use Tables W2 and X1
Direct Test
15kV
67DL -W5X
N2,5,22
Elbow
Connector
25kV
273DL -W5X
N2,5,22
Direct Test
15kV
67DEL -W5X
N5,10,18,22
Repair Elbow
Connector
25kV
273DEL -W5X
N5,10,18,22
Direct Test
15kV
68DEL -W5X
N5,10,18,22
Repair Elbow
Connector
25kV
27 DEL -W5X
N5,10,18,22
w/Test Point
Fused Elbow 15kV
68 L H-W0X
(Full Range 25kV
27 L H-W0X
Current Limiting)
See Product Guide
PG-PC-H
Bolted Elbow 15kV
67L T-W5X
N17
w/ Tap
Use Tables W4 and X1
Bushing Insert
15kV
60 A
N4,8,20
25kV
270 A
N4,8,20
35kV
370 A
N6,21
35kV
370 A3
N8,21
Extended
15kV
60 EA
N8,20
Bushing
25kV
270 EA
N8,20
Insert
Feed-Thru
15kV
602A3
N16
Insert
25kV
2702A
N16
35kV
3702A
N6,16
Insulated Cap 15kV
60D
N9
Insulated Cap 15kV
60D G
N9
w/ Ground
15kV
67D G
N7,9
25kV
273D G
N7,9
35kV
375D G
N7,9
N1. Copper lug for use on COPPER CONDUCTOR ONLY.
N2. W5X indicates that the part number includes 02500X long bi-metal compression lug as standard.
For an all-copper lug, replace W5X with W2X in Table X1 to specify the all-copper 02702X lug.
N3. Also available as housing only. Specify: 165BLR-W; 275BLR-W;
375BLR-W; 166BLR-W; 276BLR-W; 376BLR-W.
N4. Also available as elbow/insert combination. Specify: 165A4-WX;
275A4-WX; 166A4-WX; 276A4-WX.
N5. Also available with 200ECS jacket seal included. Add - “S” suffix to part number.
N6. Rated for single-phase applications only.
N7. Equipped with insulated cuff.
N8. Includes internal torquing feature using 200AT Assembly Tool.
N9. Also available without probe. Specify “A” suffix - Example: 273DRGA.
N10. Repair elbow has extended length contact and elbow housing resulting in a net gain of
3-1/4” in length.
N11. Replacement elbow has extended length contact and elbow housing resulting in a net
gain of 8-7/8” in length.
N12. Rated for 25kV thru 35kV applications.
N13. Includes long bi-metal contact 00400X.
N14. 160CA Cable Size Adapter can only be used with elbow part numbers 165LR/166LR C size only.
N16. Fully rotatable for 360° positioning. Includes bail assembly to secure feed-thru insert to bushing well.
N17. Includes 02800X bi-metal contact.
N18. Includes 02509X long bi-metal contact.
N19. Includes built-in jacket seal. Also available as housing only — specify: 165BLRJS-W,
166BLRJS-W, 275BLRJS-W or 276LRJS-W. Also available as elbow/insert combination
— specify: 165JSA4-W5X, 166JSA4-W5X, 275JSA4-W5X or 276JSA4-W5X.
N20. Includes a yellow seating indicator and vent ring.
N21. Includes a black vent ring.
N22. Direct Test Connectors, along with a 200TC-X series meter adapter, a properly rated
voltage meter and Hot-line Stick provides a means for direct conductor voltage testing.
N23. With stainless steel bracket.