Página 63 - elastimold

Versión de HTML Básico

Separable Connectors
200A Deadbreak
CABLE ACCESSORIES
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
Elbow Connector 15/25kV
56L -W5X
N1,2
w/ Test Point
Use Tables W4 and X1
Direct Test
15/25kV
56DL -W5X
N1,2,22
Elbow Connector
Use Tables W4 and X1
Bail Assembly 15/25kV
50BA
for 156LR Elbow
Bushing Insert 15/25kV
K 50 A
N3
Feed-thru Insert 15/25kV
K 502A
N3,4
Insulated Plug 15/25kV
K 50DP
N3
Insulated Cap 15/25kV
K 50D
N3
Insulated Parking 15/25kV
K 5 S P
N3
Bushing
Grounding Plug 15/25kV
5 GP
N3
Feed-Thru 15/25kV
K 50 T
N3,6
2-Point Junction 15/25kV
K 50 J2-U
N3,6
3-Point Junction 15/25kV
K 50 J3-U
N3,6
4-Point Junction 15/25kV
K 50 J -U
N3,6
Elbow Probe 15/25kV
56L
Straight
15/25kV
K 5 S -W0X
N3,12,13,
Receptacle
Use Tables W1A and X1
17,18
Straight Plug 15/25kV
K 5 SP-W0X
N3,12,13,
Use Tables W1A and X1
19
Tee Splice 15/25kV
K 50T
N3
In-Line Junction 15/25kV
K 50S
N3
Locking Splice/ 15/25kV
K 5 LS-W0X
N8,9,13,
Repair Splice
Use Tables W1A and X1
15,16,17,
20,23
Locking “Y”
15/25kV
K 5 LY-W0X
N8,9,13,
Splice
Use Tables W1A and X1
15,17,21
BAIL
15/25kV
50TB
N5
BAIL
15/25kV
50TB2
N5
BAIL
15/25kV
50TB3
N5
N1. Includes bail assembly.
N2. W5X indicates that the part number includes a 02500X bi-metal com-
pression lug, which is rated for either aluminum or copper conductor,
as standard. For an all-copper lug, replace W5X with W2X in Table
X1 to specify the all-copper 02702X lug.
N3. Bails are required but not included. Order separately. Consult factory
for bails not listed for a specific application.
N4. Fully rotatable for 360º positioning. Includes bail assembly to secure
feed-thru insert to bushing well. Elbows bail assemblies are required
but not included with the feed-thru insert.
N5. Refer to factory for application details.
N6. Center-to-center spacing equals 4 inches.
N7. Copper lug for copper cable only.
N8. To order cable legs for different cable sizes, list each leg size “W”
and “X”. Example: K151LY-A1240-A1240-B1220. See Tables W1
and X1 for sizes.
N9. To order locking contacts for K151LS and K151LY, order 01401X
(Al) or 01402X (Cu) for plug contact. Order 01301X (Al) or 01302X
(Cu) for receptacle. See Table X1 for sizes.
N10. For use with 156LR elbows.
N11. For use with K151SR, K151SP, K151LS, K151LY receptacles, plugs
and splices.
N12. Also available as housing only. Specify K151BSP-W or K151BSR-W.
N13. Also available in EB-FA sizes per table W6 by using 160CA cable
adapter with C size plugs & receptacles.
N14. 160CA cable adapter can only be used with C size plugs & recep-
tacles.
N15. Bails are not required for locking splices.
N16. When used as a repair splice, the assembled length allows 4” for
cabl replacement/repair.
N17. Straight receptacles are also available with test point. Specify K152SR-
W0X part number.
N18. W0X indicates that the part number includes a 01500X universal
aluminum compression lug, which is rated for either aluminum or
copper, as standard. For an all-copper lug, replace W0X with W2X
in Table X1 to specify the all-copper 01502X lug.
N19. W0X indicates that the part number includes a 01600X universal
aluminum compression lug, which is rated for either aluminum or
copper, as standard. For an all-copper lug, replace W0X with W2X
in Table X1 to specify the all-copper 01602X lug.
N20. W0X indicates that the part number includes a 01400X universal
aluminum compression lug, which is rated for either aluminum or
copper, as standard. For an all-copper lug, replace W0X with W2X
in Table X1 to specify the all-copper 01402X lug.
N21. W0X indicates that the part number includes a 01300X universal
aluminum compression lug, which is rated for either aluminum or
copper, as standard. For an all-copper lug, replace W0X with W2X
in Table X1 to specify the all-copper 01302X lug.
N22. Direct Test Connectors, along with a 200TC-X series meter adapter,
a properly rated voltage meter and Hot-line Stick provides a means
for direct conductor voltage testing. See page 7 for meter adapters.
N23. Gains approximately 4” of repair length.
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
BAIL
15/25kV
50TB
N5
BAIL
15/25kV
50TB5
N5
Contacts:
Long Bi-Metal 15/25kV
02500X
Copper
15/25kV
02702X
N7
Elbow 15/25kV
0EP-W
N10
Cable Entrance
Use Table W6
Insulating Plug
Cable Entrance 15/25kV
52EA-W
N11
Insulating Plug
Use Table W6
Cable Size 15/25KV
60CA-W
N14
Adapter
Use Table W6
EB-FA Only
200 Amp Deadbreak
Refer to the
W
and
X
tables on pages 38 and 39 for sizing to cable
insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.