Separable Connectors
600 Series Deadbreak
CABLE ACCESSORIES
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
600 Series Elbow 15/25kV
K655L -W0X
N1,2,12
(w/ Insul. Plug, Cap, Stud,
Use Tables W7 and X6
Lug and Cable Adapter)
35kV
755L -W0X
N1,2,12
Use Tables W9 and X6
600 Series Direct 15/25kV
K655DL -W0X
N1,2,12,14
Test Elbow
(w/ Insul. Plug, Cap, Stud
35kV
755DL -W0X
N1,2,12,14
Lug and Cable Adapter)
600 Series Elbow 15/25kV
K656L -W0X
N1,2,12
w/ Test Point
Use Tables W7 and X6
(w/ Insul. Plug, Cap, Stud,
35kV
756L -W0X
N1,2,12
Lug and Cable Adapter)
Use Tables W9 and X6
600 Series Direct 15/25kV
K656DL -W0X
N1,2,12,14
Test Elbow w/Test Point
Use Tables W7 and X6
(w/ Insul. Plug, Cap, Stud,
35kV
756DL -W0X
N1,2,12,14
Lug and Cable Adapter)
Use Tables W9 and X6
600 Series Elbow 15/25kV
K655BL
N1,3
Housing only 35kV
755BL
N1,3
(w/ Stud)
600 Series Elbow 15/25kV
K656BL
N1,3
w/ Test Point
35kV
756BL
N1,3
Housing only
(w/ Stud)
600 Series 15/25kV
K655B L
N,16
Replacement Elbow
Housing only
w/o Test Point
600 Series 15/25kV
K656B L
N,16
Replacement Elbow
Housing only
w/ Test Point
600 Series Straight 15/25kV
K655S -W0X
N1,2,11
Receptacle
Use Tables W7 and X6
(w/ Cable
Adapter, Lug &
Retaining Ring)
600 Series Direct 15/25kV
K655DS -W0X
N1,2,11,14
Test Straight
Use Tables W7 and X6
Receptacle
Elbow
600 Series Straight 15/25kV
K655BS
N1,11
Receptacle Housing
(Lug & Cable
Adapter not included)
Straight Receptacle 15/25kV
K650S A
N1,4
Adapter
600 Series 15/25kV
K655BVS
N1,9
Vault Stretcher
(Housing only 35kV
755BVS
N1,9
w/ Stud)
Cable Size 15/25kV
655CA-W
Adapter
Use Table W7
35kV
755CA-W
Use Table W9
Compression ALL
03700X
N5
Lug
Use Table X6
ALL
03702X
N6
Use Table X6
600 Series Elbow 15/25kV
655CK-W0X
N2
& Vault Stretcher
Use Tables W7 and X6
Size Sensitive Kit
(Cable Adapter 35kV
755CK-W0X
N2
& Lug)
Use Tables W9 and X6
Adapter
ALL
650A -X
Retaining Ring
Use Table X6
600 Series Straight 15/25kV
655CK-W0X-A
N2
Receptacle Size
Use Tables W7 and X6
Sensitive Kit (Cable
Adapter, Retaining
Ring & Lug)
Bushing
15/25kV
K655BE
N1,3
Extender
35kV
755BE
N1,3
(w/ Stud)
Insulated Cap 15/25kV
K656D
N3,7
w/ Test Point
(w/ Stud)
Insulating Plug 15/25kV
K650B P
N1,7,8
(w/ Cap)
35kV
750B P
N1,7,8
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
Grounding Plug 15/25kV
650GP
N1,7,8
(Ground Lead 35kV
750GP
N1,7,8
2/0 AWG x 30”)
Insulated
15/25kV
K650S P
N7,8
Parking Bushing 35kV
750S P
N7,8
Connecting Plug 15/25kV
K650CP
N1,7,8,9,13
15/25kV
K65 CP
N1,7,8,10
35kV
750CP
N1,7,8,10
Deadbreak 15/25kV
K650 TP
N1,7,8,9
Reducing
Tap Plug
Reducing Tap 15/25kV
K650 TW
N1,7,8,9
Well
Loadbreak
15kV
650ETP
N1,7,8,10,12
Elbow
25kV
K650ETP
N1,7,8,10,12
Tap Plug
35kV
750ETP
N1,7,8,10,12
Vault Stretcher 15/25kV
650VSA
N1
Threaded Stud 35kV
750VSA
N1
600 Series Elbow 15/25kV
650SA
N1
Threaded Stud 35kV
750SA
N1
Assembly Tool
ALL
600AT
N12
(Window-Op)
Spanner Wrench ALL
600SW
N9
Direct Voltage Test
ALL
Meter Adapter for:
HD Electric Meters
200TC-
N14
Ross Meters
200TC-2
N14
Chance Meters
200TC-
N14
600 Series Deadbreak
N1. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656;
K671 for K651; K675 for K650 and K655; K676 for K656; 775 for 750
and 755; 776 for 756 and 2X for 0X in the part number. The 900 Amp
rating requires copper current-carrying connector components and
copper conductor cable.
N2. Add suffix symbol from page 29 to include cable shield grounding kit
and/or cable jacket sealing kit.
N3. Available without the stud by adding “N” to the part number.
N4. Straight Receptacle Adapter is used to connect Straight Receptacles
K655YBSR and K655YSR-W0X (Pg.19) to equipment bushings.
N5. Aluminum lug for use on aluminum or copper conductors. DO NOT
substitute threaded 03600X lug.
N6. Copper lug for use on COPPER CONDUCTOR ONLY. D
substitute threaded 03602X lug.
N7. Available with the stud factory-assembled by adding “SP” to the part
number. 675ETP, K675ETP and 775ETP are available as -SP only.
The stud is not field removable.
N8. Available with a loose stud by adding suffix “S” to the part number.
N9. 600SW spanner wrench is recommended for installation of K650CP
connecting plug, deadbreak reducing tap plugs and reducing tap
wells.
N10. Use 600ATM Assembly Tool.
N11. 600 Series Elbows and Straight Receptacles with IEEE Std. 386
capacitive test points are available by substituting 656 for 655; K656
for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675
and 776 for 775 in the part number.
N12. See page 17 for Window-Op Connector Kit.
N13. Superseded by K651CP.
N14. Direct Test Connectors, along with a 200TC-X series meter adapter,
a properly rated voltage meter and Hot-line Stick; provides a means
for direct conductor voltage testing.
N15. With stainless steel bracket.
N16. Replacement Elbow includes an I-Adapter, and Straight Receptacle,
resulting in a net gain of 20”.
Refer to the
W
and
X
tables on pages 38 and 39 for sizing to cable
insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.