Separable Connectors
600 Ser. DB (Cam-
p, Link-
p)
CABLE ACCESSORIES
llustration Description Voltage
ELAST LD
otes
(not to scale)
Class
Part umber
CAM-OP 15kV
655L K-C-L -W0X-B-D G
N1,3,11,
CONNECTOR
Use Tables W7 and X6
13,14,18
KIT 25kV
K655L K-C-L -W0X-B-D G
N1,3,11,
Use Tables W7 and X6
13,14,18
35kV
755L K-C-L -W0X-B-D G
N1,3,11,
Use Tables W9 and X6
13,14,18
LINK-OP 15kV
655L K-B-L -W0X-B-D G
N2,3,11,12
CONNECTOR
Use Tables W7 and X6
13,14,18
KIT 25kV
K655L K-B-L -W0X-B-D G
N2,3,11,
Use Tables W7 and X6
13,14,18
35kV
755L K-B-L -W0X-B-D G
N2,3,11,
Use Tables W9 and X6
13,14,18
Mountable 25kV
K650LB -3
N3
Insulated
35kV
750LB -3
N3
Bushing
RETROFIT 15kV
655L K-C-L -W0X-A-D G
N5,11,13
CAM-OP
Use Tables W7 and X6
1
4,18
CONNECTOR 25kV
K655L K-C-L -W0X-A-D G
N5,11,13
KIT
Use Tables W7 and X6
14,18
35kV
755L K-C-L -W0X-A-D G
N5,11,13
Use Tables W9 and X6
14,18
RETROFIT 15kV
655L K-B-L -W0X-A-D G
N6,11,12,
LINK-OP
Use Tables W7 and X6
13,14,18
CONNECTOR 25kV
K655L K-B-L -W0X-A-D G
N6,11,12,
KIT
Use Tables W7 and X6
13,14,18
35kV
755L K-B-L -W0X-A-D G
N6,11,12,
Use Tables W9 and X6
13,14,18
Insulating 25kV
K650LB
N4
Plug 35kV
750LB
N4
CAM-OP 15kV
650CAB
Alignment
25kV
K650CAB
Bracket
35kV
750CAB
LINK-OP
ALL
650AB
N15
Alignment
ALL
650ABV
N15
Bracket (Retrofit
LINK-OP Only)
Compression ALL
03700X
N7
Lug
Use Table X6
N8
ALL
03702X
Use Table X6
CAM-OP & 15/25kV
655CK-W0X
N13
LINK-OP Size
Use Tables W7 and X6
Sensitive Kit 35kV
755CK-W0X
N13
(Cable Adapter
Use Tables W9 and X6
& Lug)
CAM-OP Re- ALL
650 SC
N11
taining Sleeve
LINK-OP ALL
650 S
N11
Retaining
Sleeve
CAM-OP 15kV
655B -L K-C-L -W X-D G
N9,11,13
CABLE JOINT
Use Tables W7 and X6
14,18
KIT 25kV
K655B -L K-C-L -W X-D G
N9,11,13
Use Tables W7 and X6
14,18
35kV
755B -L K-C-L -W X-D G
N9,11,13
Use Tables W9 and X6
14,18
LINK-OP 15kV
655B -L K-B-L -W X-D G
N10,11,12,
CABLE JOINT
Use Tables W7 and X6
13,14,18
KIT 25kV
K655B -L K-B-L -W X-D G
N10,11,12,
Use Tables W7 and X6
13,14,18
35kV
755B -L K-B-L -W X-D G
N10,11,12,
Use Tables W9 and X6
13,14,18
CAM-OP 15kV
650LK-C-VB
Loadbreak 25kV
K650LK-C-VB
Reducing 35kV
750LK-C-VB
Tap Plugs
(Visi-Break)
LINK-OP 15kV
650LT-B
N11
Loadbreak 25kV
K650LT-B
Reducing 35kV
750LT-B
Tap Plug
llustration Description Voltage ELAST LD otes
(not to scale)
Class Part umber
Grounding 15kV
60GL
Elbow 25kV
370GL
N19
(1/0 AWG x 6’ 35kV
370GL
N19
Ground Lead)
Test Rod ALL
370T
Assembly Tool ALL
600AT
N11
C -O 15kV
650CA - K
N16
O
25kV
K650CA - K
N16
K
35kV
750CA - K
N16
L -O 15kV
650L K- K
N17
O
25kV
K650L K- K
N17
K
35kV
750L K- K
N17
AB ABV
N1. Cam-Op connector kit includes: 1- Cam-Op link; 1- elbow housing;
1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer
sleeves; 1- insulated cap; 1- mountable insulated bushing and 1-
alignment bracket.
N2. Link-Op connector kit includes: 1- Link-Op link; 1- elbow housing;
1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer
sleeves; 2- insulated caps; and 1- mountable insulated bushing.
N3. Mountable insulated bushing included with Cam-Op and Link-Op
connector kit. Requires 3 threaded studs on equipment faceplate for
installation.
N4. Use with the Retrofit Cam-Op and Retrofit Link-Op connector kit.
N5. Retrofit Cam-Op connector kit includes: 1- link; 1- elbow housing;
1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer
sleeves; 1- insulated cap; 1- insulating plug; and 1- alignment
bracket.
N6. Retrofit Link-Op connector kit includes: 1- link; 1- elbow housing;
1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer
sleeves; 2- insulated caps; 1- insulating plug; and 1- alignment
bracket.
N7. Aluminum lug for use on aluminum or copper conductors. DO NOT
substitute threaded 03600X lug.
N8. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT sub-
stitute 03602X threaded lug.
N9. Cam-Op Cable Joint Kit includes: 1- Cam-Op link; 1- Cam-Op BI-
SOP; 2- elbow housings; 2- cable adapters; 2- 0370 style lugs; 2- re-
tainer sleeves; 1- insulated cap.
N10. Link-Op Cable Joint Kit includes: 1- Link-Op link; 1- Link-Op BI-SOP;
2- elbow housings; 2- cable adapters; 2- 0370 style lugs; 2- retainer
sleeves; 2- insulated caps.
N11. 600AT assembly tool required for operation and/or installation of
Link-Op. 600ATM is recommended for installing Link-Op/Cam-Op
retaining sleeves.
N12. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for 656;
K675 for K650 and K655; K676 for K656; 775 for 750 and 755;
776 for 756 and 2X for 0X in the part number. The 900 Amp rating
requires copper current-carrying connector components and copper
conductor cable.
N13. Add suffix symbol from page 29 to include cable shield grounding kit
and/or cable jacket sealing kit.
N14. To add elbows or arresters instead of insulating caps, replace the
“DRG” with “LR-WX” for elbows (with test point) or “ESA” for elbow
arresters.
N15. The 650ABV is required when the bushing horizontal spacing on the
equipment or junctions is less than 5”.
N16. Cam-Op operating kit includes accessories that enable visible break,
testing, isolation and grounding functions to be performed. Kit
includes: 3- Cam-Op loadbreak reducing tap plugs; 3- grounding
elbows; 1- assembly tool; 1- test rod; 1- carry case; 1- lubricant; 1-
instructions.
N17. Link-Op operating kit includes accessories that enable visible break,
testing, isolation and grounding functions to be performed. Kit
includes: 6- Link-Op loadbreak reducing tap plugs; 3- grounding
elbows; 1- assembly tool; 1- test rod; 1- carry case; 1- lubricant; 1-
instructions.
N18. 600 Series Elbows and Straight Receptacles with IEEE Std. 386 ca-
pacitive test points are available by substituting 656 for 655; K656 for
K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and
776 for 775 in the part number.
N19. Rated for both 25kV and 35kV applications.
600 Series Deadbreak – Cam-Op™, Link-Op™
Refer to the
W
and
X
tables on pages 38 and 39 for sizing to
cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.