Página 71 - elastimold

Versión de HTML Básico

Separable Connectors
600 Ser. DB (Stick-
p,
Window-
p)
CABLE ACCESSORIES
llustration Description Voltage ELAST LD
otes
(not to scale)
Class Part umber
WINDOW-OP 15kV
655ETP-W0X-D G
N1,4,5,6
Connector Kit
Use Tables W7 and X6
13,15
25kV
K655ETP-W0X-D G
Use Tables W7 and X6
35kV
755ETP-W0X-D G
Use Tables W9 and X6
WINDOW-OP 15kV
655 ETP
N4,5,6
Replacement
13,15,16
Connector Kit
25kV
K655 ETP
STICK-OP 15kV
655L TP-W0X-D G
N2,3,4,5,
Connector Kit
Use Tables W7 and X6
8,13
25kV
K655L TP-W0X-D G
Use Tables W7 and X6
35kV
755L TP-W0X-D G
Use Tables W9 and X6
STICK-OP
15kV
655 L TP
N3,4,5
Replacement
8,13,16
Connector Kit
25kV
K655 L TP
WINDOW-OP 15kV
650ETP
N4,15
Loadbreak 25kV
K650ETP
N4,15
Elbow 35kV
750ETP
N4,15
Tap Plug
STICK-OP 15kV
650L TPA3
N3,4
Loadbreak 25kV
K650L TPA2
Reducing 35kV
750L TPA2
Tap Plug
STICK-OP 15kV
650BEA3
N3,4
Bushing 25kV
K650BEA2
Adapter
35kV
750BEA2
Compression ALL
03700X
N6
Lug
Use Tables X6
WINDOW-OP ALL
03702X
N7
Use Tables X6
Threaded ALL
03600X
N8
Compression
Use Tables X6
Lug
ALL
03602X
N9
STICK-OP
Use Tables X6
WINDOW-OP 15/25kV
655CK-W0X
N5
Size Sensitive Kit
Use Tables W7 and X6
(Cable Adapter 35kV
755CK-W0X
N5
& Lug)
Use Tables W9 and X6
STICK-OP 15/25kV
655TCK-W0X
N5
Size Sensitive Kit
Use Tables W7 and X6
(Cable Adapter 35kV
755TCK-W0X
N5
& Threaded Lug)
Use Tables W9 and X6
Extraction Tool
ALL
650ET
N10
Grounding
15kV
60GL
Elbow 25kV
370GL
N14
(1/0 AWG x 6’
35kV
370GL
N14
Ground Lead)
Test Rod ALL
370T
Assembly Tool
ALL
600AT
N3
(Stick-Op)
Assembly Tool
ALL
600AT
N15
(Window-Op)
STICK-O 15kV
650ST CK- K
N11
O
25kV
K650ST CK- K
N11
K
35kV
750ST CK- K
N11
WINDOW-O 15kV
650W D W- K
N12
O
25kV
K650W D W- K
N12
K
35kV
750W D W- K
N12
N1. Window-Op Kit includes: insulated cap; Window-Op reducing tap
plug; 600 Series elbow housing; cable adapter; and 0370 style
compression lug.
N2. Stick-Op Kit includes insulated cap; Stick-Op Loadbreak
reducing tap plug; 600A Elbow Housing; cable adapter; and
threaded 0360 style compression lug.
N3. 600AT assembly tool required for operation and/or installation of
Stick‑Op.
N4. For 900 Amp ratings, substitute 675 for 650 and 655; 676 for
656; K675 for K650 and K655; K676 for K656; 775 for 750 and
755; 776 for 756 and 2X for 0X in the part number. The 900 Amp
rating requires copper current-carrying connector components
and copper conductor cable.
N5. Add suffix symbol from page 29 to include cable shield
grounding kit and/or cable jacket sealing kit.
N6. Aluminum lug for use on aluminum or copper conductors. DO
NOT substitute threaded 03600X lug.
N7. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT
substitute 03602X threaded lug.
N8. Threaded aluminum lug (Stick-Op only) for use on copper or
aluminum conductors. DO NOT substitute unthreaded 03700X
lugs. DO NOT use with 675, 676, K675, K676, 775 or 776 part
numbers.
N9. Threaded copper lug (Stick-Op only) for use on copper
conductors only. DO NOT substitute unthreaded 03702X lugs.
N10. Required to disassemble Stick-Op loadbreak reducing tap plug
from the threaded compression lug and 600 Series elbow after
the shear-pin is broken during assembly.
N11. Stick-Op Operating Kit includes accessories that enable visible
break direct testing, isolation, and grounding functions to
be performed. Kit includes: 3-insulated parking bushings; 3-
grounding elbows; 3-600DB/200LB bushing/elbow adapters;
1-assembly tool; 1-test rod; 1-carry case; 1-lubricant; 1-
instructions.
N12. Window-Op Operating Kit includes accessories that enable
visible grounding and direct testing functions to be performed.
Kit includes: 3-grounding elbows; 1-test rod; 1-carry case; 1-
lubricant; 1-instructions.
N13. 600 Series Elbows and Straight Receptacles with IEEE Std. 386
capacitive test points are available by substituting 656 for 655;
K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676
for K675 and 776 for 775 in the part number.
N14. Rated for both 25kV and 35kV applications.
N15. 600ATM assembly tool required for Window-Op assembly.
50 – 60 ft/lbs torque wrench required but not included.
N16. Replacement Elbow includes: insulated cap; reducing tap plug;
600 series elbow housing; I-Adapter; straight receptacle,
resulting in a net gain of 20” in length vs. a standard elbow kit.
Compression lugs and cable adapters are ordered separately.
600 Series Deadbreak – Stick-Op™, Window-Op™
Refer to the
W
and
X
tables on pages 38 and 39 for sizing to
cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.