Separable Connectors
600 Ser. DB (Cable Joints)
CABLE ACCESSORIES
llustration
Description Voltage ELAST LD otes
(not to scale)
Class Part umber
Separable 15/25kV
K656 -W0X
N1,8
Straight Joint Pkg.
Use Tables W7 and X6
(2-way)
w/ Test Point
Basic Housing Pkg. 15/25kV
K656 -HP
N2
Straight Joint
w/ Test Point
Separable 15/25kV
K656CY-W0X
N1,8
Wye Joint Pkg.
Use Tables W7 and X6
(3-Way)
w/ Test Point
Basic Housing Pkg. 15/25kV
K656CY-HP
N2
Wye Joint
w/ Test point
Separable 15/25kV
K656CH-W0X
N1,8
“H” Joint Pkg.
Use Tables W7 and X6
(4-Way)
w/ Test Point
Basic Housing Pkg. 15/25kV
K656CH-HP
N2
“H” Joint
w/ Test Point
2-Way
15/25kV
K656 -BUS
N3
Insulated Bus Bar
w/Test Point
3-Way
15/25kV
K656CY-BUS
N3
Insulated Bus Bar
w/Test Point
4-Way
15/25kV
K656CH-BUS
N3
Insulated Bus Bar
w/Test Point
Straight
15/25kV
K655YS -W0X
N4,8
Receptacle
Use Tables W7 and X6
Direct Test Straight 15/25kV
K655YDS -W0X
N4,8,11
Receptacle Elbow
Use Tables W7 and X6
Direct Test Straight 15/25kV
K656YDS -W0X
N4,8,11
Receptacle Elbow
Use Tables W7 and X6
w/ Test Point
Straight
15/25kV
K655YBS
N5,10
Receptacle
Housing
Only
Insulated Cap 15/25kV
K655YD
w/ Bail
Bail
15/25kV
650BA
Only
Cable Adapter 15/25kV
655CA-W
Use Table W7
Adapter
15/25kV
650A -X
Retaining Ring
Use Table X6
Compression Lug 15/25kV
03700X
N7
15/25kV
03702X
N9
Use Table X6
600 Series
15/25kV
655CK-W0X-
N8
Straight Receptacle
A
Size Sensitive Kit
Use Tables W7 and X6
(Cable Adapter,
Retaining Ring
& Lug)
N1. Complete Joint Packages consisting of: insulated bus bar; straight
receptacle housings, retaining rings, cable size adapters, lugs, bolts
and washers.
N2. Housing Packages consisting of the following non-size sensitive
components of the joint: insulated bus bar, straight receptacle
housings, bolts and washers.
N3. Insulated bus bar only.
N4. Straight Receptacle consisting of: straight receptacle housing,
retaining ring, cable adapter, lug, bolt and washers.
N5. Straight receptacle housing consisting of: straight receptacle housing,
bolt and washers.
N6. Recommended for ease of assembly/disassembly of receptacles to
Bus. 600 YADT is lever drive & 600RRT is screw drive.
N7. Aluminum lug for use on aluminum or copper conductors. DO NOT
substitute threaded 03600X lug.
N8. Add suffix symbol from page 29 to include cable shield grounding kit
and/or cable jacket sealing kit.
N9. Copper lug for use with COPPER CONDUCTOR ONLY. DO NOT
substitute threaded 03602X lug.
N10. Available without the bolt & washers by adding “N” to the part number.
N11. Direct Test Connectors, along with a 200TC-X series meter adapter, a
properly rated voltage meter and Hot-line Stick; provides a means for
direct conductor voltage testing. See page 11 for meter adapters.
llustration
Description Voltage ELAST LD otes
(not to scale)
Class Part umber
Insulating Plug w/ 15/25kV
K650YB P
Test Point & Cap
Grounding Plug 15/25kV
650YGP
(4/0 AWG x 6’
Ground Lead)
Grounding Cap 15/25kV
650GYD
(4/0 AWG x 6’
Ground Lead)
Stainless Steel
15/25kV
650BAW
Bolt & Washers
Assembly/
ALL
600YADT
N6
Disassembly
Tool
Assembly/
ALL
600 T
N6
Disassembly
Tool
600 Series Deadbreak – Cable Joints
Refer to the
W
and
X
tables on pages 38 and 39 for sizing to cable
insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page 28.